logo-new-homepage-red-1
d

Proven fire-safe and durable characteristics. Its core is composed of non-combustible minerals, it neither catches fire nor permit propagation of flame and restrict development of smoke.

Key Benefits
  • Reaction to fire classification A2-s1, d0 (EN 13501-1)
  • Extremely durable
  • Resistant to extreme weather
  • Wide Range of Colours
  • Different surface finishes
  • Lightweight and rigid
  • Low cost fabrication
  • Up to 20 years warranty
  • Certified and Tested
Full Details

ALUCOPANEL® A2 is composed of two sheets of High Grade 3105 aluminum alloy H16 temper with 0.50 mm thickness on Top (Coated with high quality PVDF paint comes in various finishes such as Solid Colors & Metallic colors ) & bottom (primer coated) that is sandwiched with mineral filled inorganic ingredients as core material, hence ALUCOPANEL® A2 made with this technology have achieved World’s highest reaction to fire classification “Class A2-s1, d0” when tested in accordance to European Standard EN 13501-1, the product is greatest suitable for any height, any building, as A2 classification is mandatory requirement in U.A.E for Super High-rise buildings, High-rise buildings, Malls, Theme Parks, Schools, Hospitals, Assembly as per Latest Edition of U.A.E Fire & Life Safety Guidelines.

Inorganic ingredients of A2 Core neither catches fire nor permit propagation of flame and restrict development of smoke. The core material is bonded with high molecular adhesives; it’s free of voids and air spaces and does not contain foamed insulation materials.

For further information, you can access the product brochures and technical documents below.

View Brochures
Applications

ALUCOPANEL® A2 is suitable for a huge range of applications in a variety of industries.

Façade / Cladding
  • Super High-rise buildings
  • High-rise buildings
  • Malls
  • Theme Parks
  • Schools
  • Hospitals
  • Any Building
Technical

Here are the sheets sizes and thicknesses available as standard along with the technical specification of ALUCOPANEL® A2.

TEST STANDARD TOLERANCE RESULT
4MM 6MM
Panel Thickness Screw Gauge/Vernier caliper (±) 0.2 mm 4 mm 6 mm
Weight of the Panel Weighing scale ± 0.5 kg/m2 8.3 kg/m2 11.1 kg/m2
Standard Width Measuring tape (±) 2 mm 1000, 1250, 1500, up to 2000 mm
Length Measuring tape (±) 2 mm up to 6000 mm
Max. 8000 mm
Skin Thickness Screw Gauge/Vernier caliper (±) 0.02 mm 0.5 mm
TEST STANDARD REQUIREMENT RESULT / CERTIFICATE REF. NO.
4MM 6MM
Reaction to Fire EN 13501-1 Class A2, s1, d0 TBW 0300135
Surface Burning
Characteristics
ASTM E84 (FSI) 25-0
(SDI) 450-0
FSI 15, SDI 15
Class A
FSI 15, SDI 30
Class A
Self Ignition
Temperature (ACP)
ASTM D 1929 Not less than 343˚C SIT (842˚F) 450˚C,
FIT (842˚F) 450˚C
SIT (842˚F) 450˚C,
FIT (842˚F) 450˚C
Self Ignition
Temperature (CORE)
SIT (950˚F) 510˚C,
FIT (950˚F) 510˚C
SIT (950˚F) 510˚C,
FIT (950˚F) 510˚C
Non-Loadbearing
Ventilated Façade System
BS 8414-1 As per standard TBW0300140
Exterior Non-Load Bearing
Wall Cladding Assemblies
NFPA 285 As per standard TBW0300204, TBW0300148
TBW0300560, TBW0300620
TBW0300649
TBW0300224
Roof Covering Assembly
(0-10˚ from the horizontal plane)
EN 13501-5:2016 BROOF(t4) TBW0300648
without any packing
material on steel structure
with 40 cm Void ideal for
canopies and feature.
Roof pitch 0˚ to 10˚
Roof Covering Assembly
with Mineral Wool Insulation
(10-70˚ from the horizontal plane)
EN 13501-5:2016 BROOF(t4) TBW0300738
With thermal insulation
fixed direct at rear face of
ACP, on Alum structure with
300 mm Void ideal for
Continuous Roof Covering.
Roof pitch: 10˚ to 70˚
Roof Covering Assembly
(10-70˚ from the horizontal plane)
EN 13501-5:2016 BROOF(t4) TBW0300739
without any packing
material on Alum structure
with 300mm Void ideal for
canopies and feature.
Roof pitch: 10˚ to 70˚
TEST STANDARD REQUIREMENT RESULT
4MM 6MM
Alloy / Temper ASTM B209 3105 - H16
Tensile Strength ASTM E8 172 - 221 N/mm2 196 N/mm2
Yield Strength ASTM E8 Min. 145 N/mm2 190 N/mm2
Elongation ASTM E8 Min. 1.0% 4.2%
Modulus of Elasticity ASTM E111 Measure Value 69 Gpa
TEST STANDARD REQUIREMENT RESULT
4MM 6MM
Peel Off Strength @ 180° ASTM D903 ≥ 10 kg/25mm 15.84 kg/25mm 23.2 kg/25mm
Climbing Drum Peel ASTM D1781 Measure Value 20.6 kg/25mm 20.6 kg/25mm
Shear Strength ASTM C 273 ≥ 3.2MPa 3.25 Mpa 3.27 Mpa
Tensile strength ASTM E8 ≥ 35 MPa for 4mm
≥ 25 MPa for 6mm
41.23 Mpa 29.83 Mpa
0.2% Proof Stress ASTM E8 Measure Value 49.0 Mpa 35.0 Mpa
Punch Shear Test ASTM D 732 ≥ 20 MPa 22.23 Mpa 20.87 Mpa
T-Bend Test ASTM D 522 2T (No Cracks) 2T (No Cracks)
Modulus of Elasticity ASTM C393 Measure Value 22,800 Mpa 22,800 Mpa
Flexural Strength ASTM D790-17 Measure Value 106.1 Mpa 106.1 Mpa
TEST STANDARD REQUIREMENT RESULT
4MM 6MM
Deflection Temperature ASTM D 648 ≥ 100˚C ≥ 250˚C ≥ 250˚C
Linear Thermal Expansion per 100˚C ASTM D 696 ≥ 2.40 mm/m/ ˚C 2.40 mm/m/ ˚C 2.47 mm/m/ ˚C
Linear Thermal Expansion Coefficient ASTM D 696 Measure Value 0.024 mm/ (m ˚C) 0.0247 mm/ (m ˚C)
Thermal Conductivity ASTM C 518 Measure Value 0.11 W/mK 0.10 W/mK
TEST STANDARD REQUIREMENT RESULT
4MM 6MM
Sound Transmission Class ASTM E413 ... STC 19
TEST STANDARD REQUIREMENT RESULT
4MM 6MM
Type / Finish PVDF / FEVE / HDPE PVDF / FEVE / HDPE
Coating Thickness ASTM D 1400 ≥ 25μm ≥ 25μm
Weathering Resistance ASTM C 481 A. Shear Strength
B. Film Adhesion
C. Impact Resistance
A. 3.75 Mpa (after exposure)
B.1.Dry Adhesion - No removal of film
B.2. Wet Adhesion - No removal of film
B.3. Boiling Water - No removal of film
C. Impact Resistance - No removal of film
Corrosion Resistance
(Humidity Resistance & Salt Spray)
AAMA 2605 A. Humidity Resistance
(@4000 hours exposure)
B. Salt Spray Resistance
(@4000 hours, 35˚C)
A. No formation of blisters
B.1 Scribed - rating of 9
B.2. Unscribed - rating of 10
Chemical Resistance ISO 2812 -1: 2014 A. Acid Resistance
B. Alkali Resistance
C. Oil Resistance
D. Solvent Resistance
A. NO CHANGE
B. NO CHANGE
C. NO CHANGE
D. NO CHANGE
Abrasion Resistance ASTM D 968 ≥ 50 L/mil 52.1 L/mil
T-Bend Test ASTM D 522 2T (No Cracks) 2T (No Cracks)
Pencil Hardness ASTM D 3363 ≥ H ≥ H
Film Adhesion
DRY (@27 ˚C)
WET (@38 ˚C, 24hrs)
BOILING (@100 ˚C, 20hrs)
AAMA 2605
(Clause 7.4)
No removal of film No removal of film
of the cross- hatched area;
No blistering was observed
Impact Resistance Test 50 kg-cm AAMA 2605
(Clause 7.5)
No removal of film No removal of film
REMARK: Coating Performance results are complying with AAMA 2605-13 Requirements
Colours

In addition to our stock range, ALUCOPANEL® A2 can also be colour matched to almost any RAL colour - allowing corporate colours to be matched with ease.

1) Above color samples displayed are for reference only, before ordering please double check the color of actual material.

2) To avoid possible reflection differences, it is imperative to install the panels in the same direction as marked on the protective film.

3) Please order the total requirements for one particular building in a single order, for metallic and solid colors, an optical change of color shade may occur due to the metallic particles of these lacquers.

4) Tolerance in color between batches: ∆E2.0 in accordance to ISO 7724-3 (EN 1396:1996)

1) Above color samples displayed are for reference only, before ordering please double check the color of actual material.

2) To avoid possible reflection differences, it is imperative to install the panels in the same direction as marked on the protective film.

3) Please order the total requirements for one particular building in a single order, for metallic and solid colors, an optical change of color shade may occur due to the metallic particles of these lacquers.

4) Tolerance in color between batches: ∆E2.0 in accordance to ISO 7724-3 (EN 1396:1996)

1) Above color samples displayed are for reference only, before ordering please double check the color of actual material.

2) To avoid possible reflection differences, it is imperative to install the panels in the same direction as marked on the protective film.

3) Please order the total requirements for one particular building in a single order, for metallic and solid colors, an optical change of color shade may occur due to the metallic particles of these lacquers.

4) Tolerance in color between batches: ∆E2.0 in accordance to ISO 7724-3 (EN 1396:1996)

1) Above color samples displayed are for reference only, before ordering please double check the color of actual material.

2) To avoid possible reflection differences, it is imperative to install the panels in the same direction as marked on the protective film.

3) Please order the total requirements for one particular building in a single order, for metallic and solid colors, an optical change of color shade may occur due to the metallic particles of these lacquers.

4) Tolerance in color between batches: ∆E2.0 in accordance to ISO 7724-3 (EN 1396:1996)

1) Above color samples displayed are for reference only, before ordering please double check the color of actual material.

2) To avoid possible reflection differences, it is imperative to install the panels in the same direction as marked on the protective film.

3) Please order the total requirements for one particular building in a single order, for metallic and solid colors, an optical change of color shade may occur due to the metallic particles of these lacquers.

4) Tolerance in color between batches: ∆E2.0 in accordance to ISO 7724-3 (EN 1396:1996)

1) Above color samples displayed are for reference only, before ordering please double check the color of actual material.

2) To avoid possible reflection differences, it is imperative to install the panels in the same direction as marked on the protective film.

3) Please order the total requirements for one particular building in a single order, for metallic and solid colors, an optical change of color shade may occur due to the metallic particles of these lacquers.

4) Tolerance in color between batches: ∆E2.0 in accordance to ISO 7724-3 (EN 1396:1996)

Bright Silver

Downloads